The import-trace tool supports a memorymap file as argument. Currently the
import tool accepts only decimal values, but the hexadecimal system is more
common to specify a memory address or range. To avoid a manual translation
between hex and dec values the patch extends the import tool to handle both
types according to the prefix of a value.
Change-Id: I79d0bc03ecf296dfbced8fb33518e8f5a5790366
Independent of the protocol specification all integer fields in the
result table are signed. For instance, if I store a kernel IP (e.g.
0xf1....) the value in the database is 0x7fffffff because of the wrong
type.
Therefore, the data fields of the result table should have the same
types as specified in the protocol.
Change-Id: I9154251e4ad67ba70fe86155ebda378c4a9982c2